ZVF300 Series High Performance Vector Control Frequency Inverter
ZVF300 series high Performance vector control frequency inverter is ZIRI Electrical developed the new type frequency inerter . General type and fan/pump type are in one model . support Modbus communication protocol. can be widely used to control and drive the speed of induction motors and synchronous motor . superior performance, abundant functions, easy operation, high accountability and a complete range of specifications.Can fully meet the individual needs of customers in the industry.
Specification
Single phase, 220V ± 20%, 0.4 to 3.7kW
Three phase, 380V ± 20%, 0.75 to 630kW
[vc_row][vc_column][vc_tta_tabs][vc_tta_section title="Main Features" tab_id="1488436276300-e9088c6f-1103"][vc_column_text]
ZVF300 Series inverters are high performance open loop vector inverters for controlling asynchronous AC induction motors and permanent synchronous motors.
1. Output frequency :0-600Hz.
2. Multiple password protection mode
3. Remote control operation keypad, convenient for remote control.
4. V/F curve &multi-inflection point setting, flexible configuration .
5. Keyboard parameter copy function. easy to set the parameters for multi-inverters .
6. Wide industry application . to expand special function according to different industries.
7. Multiple hardware and software protection and optimized hardware for anti-interference technology.
8. Multi-step speed and wobble frequency running (external terminal 15 steps speed control).
9. Unique adaptive control technology . Auto current limiting and voltage limiting and under-voltage restrain .
10. Optimized external installation and internal structure and independent air flue design , fully enclosed electrical space design .
11. Output automatic voltage regulation function .(AVR),automatically adjust the output pulse width . to eliminate the influence of the grid change on load .
12. Built-in PID regulation function to facilitate the realization of closed loop control of the temperature ,pressure and flow . and reduce the cost of the control system .
13. Standard MODBUS communication protocol . easy to achieve the communication between PLC,IPC and other industrial equipments.
[/vc_column_text][/vc_tta_section][vc_tta_section title="Specification" tab_id="1488436276360-de44b075-0f8b"][vc_column_text]
Input Voltage (V) | Output Voltage(V) | Power Range (kW) |
Single phase 220V± 20% | Three phase 0~Input Voltage | 0.4kW~2.2kW |
Three phase 380V ± 20% | Three phase 0~Input Voltage | 0.75kW~630kW |
Overload capacity :150% 1 minute; 180% 1 second;200% transient protection |
Inverter Model | Power (kW) G/P |
Current (A) |
Dimension (mm) | Figure | |||||
H | H1 | W | W1 | D | d | ||||
ZVF300-G0R4S2MD | 0.4 | 2.4 | 185 | 175 | 118 | 108 | 170 | Ф4 | Fig.1 |
ZVF300-G0R7S2MD | 0.75 | 7.5 | |||||||
ZVF300-G1R5S2MD | 1.5 | 7.0 | 185 | 175 | 118 | 108 | 190 | Ф4 | |
ZVF300-G2R2S2MD | 2.2 | 10 | |||||||
ZVF300-G0R7T4MD | 0.75 | 2.5 | 185 | 175 | 118 | 108 | 170 | Ф4 | Fig.1 |
ZVF300-G1R5T4MD | 1.5 | 3.7 | |||||||
ZVF300-G2R2T4MD | 2.2 | 5.0 | |||||||
ZVF300-G3R7/P5R5T4MD | 3.7/5.5 | 9.0/13 | 215 | 205 | 145 | 135 | 193 | Ф4 | |
ZVF300-G5R5/P7R5T4MD | 5.5/7.5 | 13/17 | |||||||
ZVF300-G7R5/P011T4MD | 7.5/11 | 17/25 | 265 | 253 | 185 | 174 | 215 | Ф5.5 | |
ZVF300-G011/P015T4MD | 11/15 | 25/33 | |||||||
ZVF300-G015/P018T4MD | 15/18.5 | 33/37 | 380 | 360 | 220 | 140 | 230 | Ф6 | Fig.2 |
ZVF300-G018/P022T4MD | 18.5/22 | 37/45 | |||||||
ZVF300-G022/P030T4M | 22/30 | 45/60 | 460 | 443 | 260 | 177 | 268 | Ф6 | |
ZVF300-G030/P037T4M | 30/37 | 60/75 | |||||||
ZVF300-G037/P045T4M | 37/45 | 75/90 | 620 | 603 | 265 | 182 | 300 | Ф8 | |
ZVF300-G045/P055T4M | 45/55 | 90/110 | |||||||
ZVF300-G055/P075T4M | 55/75 | 110/150 | |||||||
ZVF300-G075/P090T4M | 75/90 | 150/176 | 720 | 702 | 365 | 240 | 360 | Ф9 | |
ZVF300-G090/P110T4M | 90/110 | 176/210 | |||||||
ZVF300-G110/P132T4M | 110/132 | 210/253 | |||||||
ZVF300-G132/P160T4M | 132/160 | 253/300 | 1190 | 493 | 390 | Fig.3 | |||
ZVF300-G160/P185T4M | 160/185 | 300/340 | |||||||
ZVF300-G185/P200T4M | 185/200 | 340/380 | |||||||
ZVF300-G200/P220T4M | 200/220 | 380/420 | 1600 | 660 | 415 | ||||
ZVF300-G220/P250T4M | 220/250 | 420/470 | |||||||
ZVF300-G250/P280T4M | 250/280 | 470/520 | |||||||
ZVF300-G280/P315T4M | 280/315 | 520/600 | |||||||
ZVF300-G315/P350T4M | 315/350 | 600/640 | 1750 | 750 | 470 | ||||
ZVF300-G350/P400T4M | 350/400 | 640/690 | |||||||
ZVF300-G400/P450T4M | 400/450 | 690/790 | |||||||
ZVF300-G450/P500T4M | 450/500 | 790/860 | 1900 | 950 | 520 | Fig.4 | |||
ZVF300-G500/P560T4M | 500/560 | 860/950 | |||||||
ZVF300-G560/P630T4M | 560/630 | 950/1100 | |||||||
ZVF300-G630T4M | 630 | 1100 |
[/vc_column_text][/vc_tta_section][vc_tta_section title="Technical Indications" tab_id="1488436560624-22a06592-bbf5"][vc_column_text]
Item |
Item Description |
|
Input |
Rated voltage& Frequency | Single /Three phase 220VAC . Three phase 380V.50Hz/60Hz |
Allowable Voltage range | Voltage fluctuate range:-20%~+20% Voltage unbalance rate:<3%;Frequency fluctuation:≤5% |
|
Output |
Rated voltage |
three phase 0~ input AC voltage |
Frequency |
0.00~600.00Hz | |
Overload capacity |
Type G:150% 1minute,180% 1 second,200% transient protection Type P:120% 1minute,150% 1 second,180% transient protection |
|
Control Function |
Modulation mode |
Optimal space voltage vector PWM modulation |
Control mode |
Sensorless vector control (SVC), V/F control . Torque control | |
Frequency accuracy |
Digital setting: Max. Frequency ×±0.01% |
|
Frequency resolution | Digital setting :0.01HZ; Analog setting :Max. Frequency x0.1%. |
|
Starting frequency |
0.00~10.00Hz | |
Torque lift |
Automatic torque lift: To lift the torque automatically according to the output current. Manual torque lift, Range: 0.1—30.0% |
|
Slip compensation |
Setting range:0~150%,The inverter output frequency can be auto-regulated within this range according to the motor load, so as to reduce the speed variation of the motor due to load fluctuation. | |
Acceleration/deceleration time |
Minutes/Seconds can be selected as time unit .0.1~3600S can be set in sequence . | |
Carrier frequency | 1.0~15.0KHz | |
Jog function | Jog frequency range:0.01~600.00Hz, Jog acceleration /deceleration time 0.1~3600.0S can be set. |
|
V/F curve | 1:linear curve;2:quadratic;3:user defined V/F curve | |
Control Function |
Automatic energy-saving operation | Auto optimize V/F curve according to the load changes to realize the energy saving operation. |
Auto voltage regulation (AVR) |
When the network voltage changes, it can regulate PWM output automatically to maintain constant voltage. | |
Built-in PID |
This can form a convenient closed-loop control system (CLCS)and is applicable to pressure control, flow control and other process control . | |
Operation Function |
Operating command |
Operation panel control ,external terminal control and COM control |
Frequency setting |
Keypad potentiometer setting , operation panel▲▼setting,. external terminal UP/DOWN setting, analog voltage signal or external potentiometer setting , analog current signal setting .terminal combination setting ,485 COM setting and so on. | |
Input Signal |
Forward/Reverse signal、multi-speed signal 、 fault signal 、 reset signal etc. |
|
Output signal |
Programmable relay、 open collector output 、 Fault signal output. | |
Multi-function analog and digital output terminal | This can realize the output of frequency current and other physical quantity by output 0-10V or 0-20mA DC signal and 0-10KHz digital signal output. | |
Braking function |
Dynamic braking |
With an external braking resistor, the maximum braking torque may reach 100%. |
DC Braking |
This can be selected when the motor starts or stops with the action frequency of 0-20Hz,action current level of 0-100% and actuation time of 0-30sec., which can be set in sequence. | |
Other Function |
Skip frequency、Jog function、 Counter 、Rotation speed tracking、 Momentary power loss restart 、Frequency upper/lower limiting、 Acceleration/ Deceleration mode can be adjusted 、Frequency meter and Voltmeter output 、Multi-speed/ program running 、Two wire mode/ three wire mode control 、Wobble frequency control、 Multi-function input terminal selection 、 Fault auto reset、RS485 serial communication . | |
Protection Function |
Input phase loss protection、 Over current protection 、Overload protection、 Over voltage protection 、Under voltage protection、 Over heat protection ect. | |
LED display |
Can display the real time running status of the inverter , monitor parameter .function parameter and fault code and other information of the inverter. | |
Matching parts |
Braking assembly, remote keypads and wire connection , communication panel . | |
Ambient |
Place to be used |
Indoor location free from direct exposure to sun light, high humidity or dew condensation, high levels of dust, corrosive gas, explosive gas, inflammable gas, oil mist, salt and etc |
Altitude |
Below 1000 M | |
Ambient Temperature | -10 C to +45 C (Bare Machine: -10 C to+50 C) | |
Humidity |
20%-90% RH without dew condensation | |
Vibration |
<0.5G | |
Storage temperature | -20~+60C | |
Structure |
Protection class |
IP20 |
Cooling mode |
Forced air cooling | |
Installation mode |
Wall mounted or floor-type actuator |
[/vc_column_text][/vc_tta_section][vc_tta_section title="Related drawings" tab_id="1488436588729-ee42395a-091e"][vc_column_text][/vc_column_text][/vc_tta_section][vc_tta_section title="Download" tab_id="1488436597474-403279a5-bd3d"][vc_row_inner][vc_column_inner width="2/3"][vc_column_text]ZVF300 Series High Performance vector control frequency inverter.pdf[/vc_column_text][/vc_column_inner][vc_column_inner width="1/3"][vc_column_text]